What size boiler for a 4-bedroom house? (UK: 28-34 kW combi, 35-42 kW with 3 bathrooms)

A 4-bedroom house with one or two bathrooms needs a 28-34 kW combi or an 18-26 kW system boiler on the UK installers' tables, the same row as a 3-bedroom house. Three bathrooms, or 20 or more radiators, move it to the top row: 35-42 kW combi or 27-40 kW system, where the sources suggest looking at a system boiler with a cylinder. Below: kW by bathrooms, by radiator count, and the heat loss by floor area.

Open the boiler size calculator

1. 4-bedroom house: combi and system kW by bathrooms

The installers' tables (Heatable, What Size Boiler Do I Need?, combi boiler sizing for typical UK homes) put 3 and 4 bedrooms in the middle row, and read the bathrooms as a second condition: the higher of the two rows applies. For four bedrooms that means the bathrooms only matter from the third one.

Table 1: boiler kW for a 4-bedroom house by bathrooms, UK installers' tables
BathroomsCombiSystem or regular
1 bathroom28-34 kW18-26 kW
2 bathrooms28-34 kW18-26 kW
3 bathrooms35-42 kW27-40 kW

The same answer for one or two bathrooms applies to a 3-bedroom house; see the 3-bedroom boiler guide for the smaller house.

2. When a 4-bed house moves to the top row

Three things move it: a third bathroom, 20 or more radiators (Heatable, What Size Boiler Do I Need?, radiator column of both tables), or a fifth bedroom. The radiator counts below reach the top row on their own: 20 and 25 radiators give 35-42 kW even with one bathroom.

Table 2: boiler kW by radiator count and bathrooms (combi, then system)
RadiatorsCombi, 1 bathroomCombi, 2 bathroomsCombi, 3 bathroomsSystem, 1 bathroom
624-27 kW28-34 kW35-42 kW12-18 kW
824-27 kW28-34 kW35-42 kW12-18 kW
1028-34 kW28-34 kW35-42 kW18-26 kW
1228-34 kW28-34 kW35-42 kW18-26 kW
1528-34 kW28-34 kW35-42 kW18-26 kW
1828-34 kW28-34 kW35-42 kW18-26 kW
2035-42 kW35-42 kW35-42 kW27-40 kW
2535-42 kW35-42 kW35-42 kW27-40 kW

These rows are the radiator reading alone. Four bedrooms already select the 28-34 kW row, so for a 4-bed house the table only adds information where it shows the top row. For one output in detail: how many radiators a 28 kW boiler can run.

3. Heat loss of a 4-bedroom house by floor area

The heating load follows floor area and insulation, not bedrooms: floor area x 130 W/m² poor, 100 W/m² average, 80 W/m² good (TradeCalculator.co.uk, Radiator Sizing Calculator, rule of thumb for whole-building heat loss per m² of floor area).

Table 3: heat loss in kW by floor area and insulation
Floor areapooraveragegood
50 m²6.50 kW5.00 kW4.00 kW
70 m²9.10 kW7.00 kW5.60 kW
90 m²11.70 kW9.00 kW7.20 kW
120 m²15.60 kW12.00 kW9.60 kW
150 m²19.50 kW15.00 kW12.00 kW
200 m²26.00 kW20.00 kW16.00 kW

A 200 m² house with poor insulation loses 26.00 kW; set that against 18-26 kW for a system boiler, which heats the radiators and a cylinder rather than water on demand. The combi boiler size calculator shows your floor area, bedrooms, bathrooms and radiators side by side; a Gas Safe installer's heat loss calculation and hot water check decide the boiler.

Frequently asked questions

What size combi boiler for a 4-bed house?
28-34 kW with one or two bathrooms, 35-42 kW with three or more (Heatable, What Size Boiler Do I Need?, combi boiler sizing for typical UK homes). A 4-bed house with 20 or more radiators is also in the 35-42 kW row on the radiator column of the same tables.
What size boiler for a 4-bed house with 2 bathrooms?
28-34 kW combi or 18-26 kW system or regular. Two bathrooms select the middle row, the same row four bedrooms already select, so the second bathroom does not change the answer; a third one does (35-42 kW combi).
Combi or system boiler for a 4-bedroom house?
The tables give both: 28-34 kW combi or 18-26 kW system with one or two bathrooms. For the top row (three or more bathrooms, 20+ radiators) the source adds "often consider a system boiler" (Heatable, What Size Boiler Do I Need?, combi boiler sizing for typical UK homes); the system row there is 27-40 kW.
Is a 28 kW combi enough for a 4-bed house?
28 kW is the bottom of the 28-34 kW row that covers a 4-bed house with one or two bathrooms, and the manufacturer's guide puts it at 10 to 15 radiators (Ideal Heating, Combi Boiler Size Guide, radiators a combi output serves). With three bathrooms or 20+ radiators the tables move to 35-42 kW.
What size boiler for a 5-bedroom house?
The top row whatever the bathrooms: 35-42 kW combi or 27-40 kW system (Heatable, What Size Boiler Do I Need?, combi boiler sizing for typical UK homes).

Last updated 2026-09-29. Sizing estimates from published charts and rules of thumb (ENERGY STAR, manufacturer guides), each with its source and date: a Manual J load calculation by an installer is the final word.